Looking for a reliable generator cord and inlet box combo that keeps your home or RV powered during outages?
Product overview
You’re looking at the 30 Amp Generator Cord 15FT and Power Inlet Box, Pre-Drilled 30 Amp Generator Inlet Box with Cord, NEMA L14-30P to L14-30R Generator Cord Waterproof Combo Kit, ETL Listed. This kit from RVINGPRO pairs a heavy-duty 15-foot 30A generator cord with a pre-drilled inlet box so you can hook your generator to your panel quickly. It’s designed to give you a weather-resistant, code-friendly connection for backup power.
What’s included
You’ll get everything needed for a basic generator-to-house hookup in one package. The kit contains the 15FT 30 amp generator cord, the pre-drilled inlet box, a cable tie, and a storage bag — plus 90 days no-reason return service.
Key specifications
This table breaks down the most important specs so you can compare at a glance. It’s useful whether you’re checking compatibility with your generator or confirming code-related details.
Feature | Specification |
---|---|
Cord length | 15 ft |
Conductor | 100% copper |
Wire gauge | 10/4 SJTW |
Male plug | NEMA 14-30P |
Female plug | NEMA L14-30R (twist-lock) |
Voltage rating | 125V/250V |
Max wattage | 7,500 W |
Inlet box | Pre-drilled (4 directions: left, right, bottom, rear) |
Weather protection | Weatherproof seal cap; indicator light on cap |
Certification | ETL Listed |
Extras | Cable tie, storage bag |
Return policy | 90 days no reason to return |
Design and build quality
You’ll notice the cord’s construction right away: 100% copper conductors and a flame-retardant PVC jacket. That combination gives you solid conductivity and a rugged outer layer that resists abrasion and weather.
The inlet box is pre-drilled in four directions so you don’t need to spend time deciding where to punch holes. The design is practical if you’re connecting from different angles or want to route the cable neatly to your transfer switch or panel.
Cord construction details
The 10/4 SJTW cable tells you the cord is suited for outdoor use and is fairly flexible for its gauge. The 10 AWG conductors are standard for 30A circuits and the SJTW rating indicates it’s oil- and water-resistant to some degree, which is helpful for generator setups that might sit in the elements.
Inlet box features
The inlet box has a spring-sealed, weatherproof cap to keep water and dust out when not in use. There’s also a green indicator light on the cap so you can visually confirm when power is present at the inlet. The pre-drilled pattern (left, right, bottom, rear) is convenient for different mounting situations and minimizes the need for additional modifications.
Safety and certification
Safety is a major factor when working with generator hookups and this kit addresses that with ETL listing on both the cord and inlet box. That certification means the components have been independently tested to meet applicable safety standards for outdoor electrical equipment.
You’ll also appreciate the twist-lock female connector (L14-30R), which prevents accidental disconnection under load. The flame-retardant jacket reduces fire risk, and the weatherproof inlet cap helps prevent moisture-related hazards.
Performance and electrical characteristics
This kit supports 125V/250V service and up to 7,500 watts at 30 amps. For most home backup scenarios using a portable generator, that wattage allows you to run critical loads — a furnace fan, refrigerator, a few lights, and some small appliances — depending on the generator’s load management and your setup.
Load expectations
At 30 amps on a 240V split-phase circuit, you’re working with a typical portable generator connection for homes and RVs. The 7,500 W maximum assumes ideal conditions, so you’ll want to ensure your generator’s rated output matches or exceeds the demands you plan to place on it.
Electrical compatibility
The supplied NEMA 14-30P male plug fits common generator outlets and the L14-30R twist-lock inlet is a standard for transfer switch or inlet installations. If your generator uses a different plug type, you’ll need an adapter or a different cord, so check compatibility before purchase.
Installation and setup
You can complete most installs with basic tools if you have moderate DIY skills. The pre-drilled inlet box cuts installation time since you won’t need to measure and drill multiple knockout locations.
Basic installation steps
- Plan the route from the generator to the inlet. Consider clearance, trip hazards, and where your transfer switch or panel connection will be.
- Mount the inlet box to a suitable surface using hardware that fits your wall type. The pre-drilled holes give you flexibility on placement.
- Connect the inlet wires to the appropriate terminals on the inlet box (follow the included wiring diagram or local code).
- Attach the female twist-lock connector to the inlet box wiring per instructions.
- Plug the cord into the generator and twist the L14-30R to lock it in place when powering up.
Tips for a smoother setup
- Use the provided cable tie to secure the cord in place and prevent strain on the connectors.
- Check local codes: some jurisdictions require a licensed electrician for permanent generator connections and transfer switch installations.
- Always shut off the main breaker or use a transfer switch when connecting a generator to prevent backfeed.
Weather resistance and outdoor use
You’ll get meaningful weather resistance from the SJTW jacket on the cord and the weatherproof inlet cap on the box. The cap keeps rain and dust out when the cord isn’t in use, and the cord jacket is designed to withstand typical outdoor conditions.
The ETL listing reinforces that these components are suitable for outdoor applications, including exposure during storms. Still, you should protect connections from prolonged direct exposure by orienting the inlet so water drains away from the connector and using an additional shelter or generator tent if needed.
Indicator light usefulness
The green indicator light on the inlet cap is a small but useful feature. You can easily tell whether your inlet is receiving power without opening the cap or interacting with your generator directly. That speeds troubleshooting and gives you a quick visual confirmation during outages or transfers.
Real-world use cases and compatibility
This kit is practical for several scenarios: RV shore power flexibility, portable generator-to-home hookup, jobsite power distribution for light equipment, and temporary power during events. If you’re running a generator with a compatible outlet and you need a tidy, code-friendly inlet to route power to your transfer switch or panel, this combo is relevant.
RV owners
If your RV or camper has a compatible inlet or you need to adapt generator power for shore connections, the 15-ft length and standard connectors make it easy to maneuver and connect. The cord’s weather resistance is beneficial for outdoor campsite use.
Home backup
For homeowners with portable generators, this kit provides a safe inlet to install on an exterior wall. Pair it with a manual transfer switch or interlock kit (installed by a qualified electrician, if required) to power critical circuits safely during outages.
Contractors and jobsite
If you’re using portable tools and need a robust temporary power solution, the twist-lock connection prevents accidental disconnects, and the cable gauge handles typical 30A loads.
Pros and cons
You’ll find a balanced view below to help you weigh the kit’s advantages and limitations. Each point is based on features, build, and real-world practicality.
Pros
- Solid 100% copper conductors for reliable conductivity and lower resistance.
- Pre-drilled inlet box saves installation time and fits multiple routing options.
- ETL listed components for safer outdoor use and code compliance confidence.
- Weatherproof cap and indicator light add practical protection and convenience.
- Twist-lock L14-30R connector secures under load, reducing accidental unplugging.
- Includes cable tie and storage bag so you get a neat package out of the box.
Cons
- 15 ft length may be short for some setups; you might need an extension or different placement for generator and inlet.
- Some local codes require electrician installation for permanent hookups, which adds cost.
- Maximum wattage (7,500 W) is limited by the 30A rating; larger whole-house needs require 50A or higher solutions.
- If your generator has a different outlet type, adapters or different cords are required.
Comparison with similar kits
When you compare this kit to other 30A inlet kits, the key differentiators are the pre-drilled inlet box, ETL listing for both components, and the indicator light. Other kits may offer different cord lengths, plastic versus metal inlet boxes, or different certification statuses.
Feature | This RVINGPRO kit | Typical budget kit | Premium kit |
---|---|---|---|
Cord length | 15 ft | 10–20 ft | 15–30 ft |
Conductor material | 100% copper | Often copper-clad aluminum | 100% copper |
Inlet box | Pre-drilled metal, 4 directions | Often single-direction, may require drilling | Pre-configured with gasketed cover |
Certification | ETL listed (both) | Sometimes uncertified | ETL/UL listed |
Indicator light | Yes | Usually no | Often yes |
Twist-lock connector | L14-30R included | Varies | Included |
You’ll find that this kit sits in a middle ground: higher quality than the cheapest options, but more cost-effective than some premium kits that add longer cords or heavy-duty metal housings.
Maintenance and care
Keep the cord and inlet box in good condition to ensure long life and reliable performance. Basic maintenance is straightforward and prevents many common issues.
Routine checks
- Inspect the cord and connectors before each season of use for cracks, exposed conductors, or loose pins.
- Make sure the inlet cap seals properly and that the indicator light functions.
- Store the cord coiled loosely in the provided bag when not in use to avoid kinks and reduce stress on the jacket.
- Wipe any moisture or debris off the inlet box and cords after storms.
Long-term care
If you leave the inlet box installed year-round, periodically remove the cap and check for corrosion or water ingress around the contacts. Replace any parts showing discoloration, pitting, or other signs of degradation.
Troubleshooting common issues
You’ll likely be able to resolve most problems with a few checks. Here are common issues and easy steps to take.
Inlet showing no power (indicator light off)
- Confirm the generator is running and producing power.
- Check the male plug (14-30P) connections to ensure it’s fully seated.
- Inspect for blown fuses or tripped breakers in the generator or transfer switch.
- Verify that any transfer device or interlock is positioned correctly.
Connector feeling hot under load
- Check that the cord is fully seated and the twist-lock connection is secure.
- Inspect for damage at the connector or pins that could increase resistance.
- Confirm the total load on the generator is within the rated 7,500 W capacity.
Moisture in the inlet
- Make sure the cap is closing fully and forming a reliable seal.
- Reposition the inlet or add a small protective awning so water doesn’t drip into the cap area.
- If corrosion is present, clean the contacts or replace affected parts as needed.
Safety reminders
You must follow safe practices when using generator cords and inlet boxes. Improper use can create backfeed or electrocution hazards.
- Never connect a generator directly to your home wiring without a transfer switch or proper interlock.
- Turn off main breakers or isolate circuits before connecting the generator.
- Use the twist-lock connection to avoid accidental disconnects while under load.
- If you’re unsure about wiring or local code requirements, hire a licensed electrician.
Who should buy this kit
This product is a good fit if you:
- Need a reliable 30A inlet and cord for portable generator backup.
- Prefer a pre-drilled inlet box to speed up installation.
- Want ETL-listed equipment for outdoor use.
- Are powering RVs, small homes, or worksites with typical 30A generator outputs.
- Appreciate a compact kit with storage and cable management included.
If you require 50A service for larger generators or whole-house automatic transfer solutions, you’ll need a different product tailored to those higher amperages.
Frequently asked questions
You’ll often have practical questions before buying; here are answers to the most common ones.
Q: Is 15 ft long enough? A: It depends on your setup. 15 ft is convenient for most close-proximity generators and inlet placements, but if your generator will sit farther from the inlet or you need more flexible positioning, plan for an extension or move the inlet location.
Q: Can I use this to power my whole house? A: Typically not. A 30A, 7,500 W limit is likely insufficient for a whole house unless you’re selectively powering a few key circuits. For whole-house systems, consider 50A or transfer switch solutions sized for your household load.
Q: Do I need an electrician to install the inlet box? A: Local codes vary. While mounting the box may be straightforward, connecting it to your electrical panel and ensuring code compliance often requires a licensed electrician. Check local regulations before beginning.
Q: Is the cord compatible with all generators? A: It’s compatible with generators offering a NEMA 14-30 outlet. If your generator uses a different receptacle, you’ll need an adapter.
Q: Is it safe in heavy rain? A: The cord is SJTW-rated for outdoor use and the inlet box has a weatherproof cap, but you should avoid leaving connections exposed in heavy rain for extended periods. Positioning and additional protection will extend life and safety.
Final verdict
If you need a convenient, well-built 30A generator cord and inlet solution for RVs, small home backup circuits, or jobsite use, the RVINGPRO 30 Amp Generator Cord 15FT and Power Inlet Box combo is a solid choice. It pairs practical features — pre-drilled inlet, ETL listing, copper conductors, weatherproof cap, and indicator light — with a sensible price and a compact package. You’ll want to confirm length and amperage meet your specific needs, and check local code requirements for permanent installations, but for many users this kit strikes a good balance between safety, convenience, and value.
If you have a specific setup or generator model in mind, tell me the details and you’ll get tailored advice on compatibility, placement, and whether this kit is the best fit for your situation.
Disclosure: As an Amazon Associate, I earn from qualifying purchases.